PT. Anugerah Tricipta Otomasi

sql
Diris A60
Hover to Zoom

Update Terakhir
25 Jun 2020
Negara Asal
France
Pembelian Min
1 Pieces

Spesifikasi

DIRIS A-60
Multifunction meters - PMD energy monitoring and event analysis - dimensions 96x96 mm
DIRIS A60 is a panel mounted multifunction meter which incorporates all functions of the DIRIS A40 with the addition of enhanced data logging functions, recording curves for quality events. All this information can be analysed remotely using the Analysis software which is available at no charge and can be downloaded from the SOCOMEC website www.socomec.com.
The functions of the DIRIS A40, the DIRIS A60:
• shows the current and voltage unbalance
• shows the tangent ϕ
• stores the load curves (60 days with an interval of 10 minutes) for the active, reactive and apparent power: ΣP+/- ; ΣQ+/-, ΣS
• detects and stores the last 40 events concerning:
- overvoltage
- voltage dips
- cut-offs
- overcurrent.
For each stored event, the DIRIS A60 records the relevant RMS 10 ms interval curves for the voltages V1, V2, V3, U12, U23, U31 and the currents I1, I2, I3, In, giving a total of 400 curves.
Other functions:
Multi-measurement
• Currents
- instantaneous: I1, I2, I3, In, Isystem,
- average/maximum average: I1, I2, I3, In,
- unbalance: I unb.
• Voltages & frequency
- instantaneous: V1, V2, V3, U12, U23, U31, F, Vsystem, Usystem
- average/maximum average: V1, V2, V3, U12, U23, U31, F
- unbalance: U unb.
• Power
- instantaneous: 3P, ΣP, 3Q, ΣQ, 3S, ΣS
- maximum average: ΣP, ΣQ, ΣS
- predictive: ΣP, ΣQ, ΣS.
• Power factor - PF, ΣPF
• Instantaneous total tangent ϕ
• Instantaneous, average and max. average unbalance
• Temperatures
- internal,
- external via 3 PT100 sensors
Metering
• Active energy: +/- kWh
• Reactive energy: +/- kvarh
• Apparent power: kVAh
• Hours:
Harmonic analysis (level 63)
• Total harmonic distortion
- Currents: thd I1, thd I2, thd I3, thd In
- Phase-to-neutral voltage: thd V1, thd V2, thd V3
- Phase-to-phase voltage: thd U12, thd U23, thd U31
• Individual
- Currents: HI1, HI2, HI3, HIn
- Phase-to-neutral voltage: HV1, HV2, HV3,
- Phase to phase voltage: HU12, HU23, HU31
Events
• Alarms on all electrical values
Communications
• 0/4- 20 mA analogue output
• RS485 MODBUS RTU
• Ethernet (MODBUS TCP or MODBUS RTU over TCP and Webserver)
• Ethernet (MODBUS TCP or MODBUS RTU over TCP and Webserver) with RS485 MODBUS RTU gateway
Inputs / Outputs
• Pulse metering
• Remote control/command
• Alarm report
• Pulse report
Power Meter

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1



Silahkan email permintaan Anda ke:
 

 


marketing@ato.co.id


 
 

Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot