Spesifikasi

Range of product: Modicon M251
Product or component type: Logic controller
[Us] rated supply voltage: 24 V DC


Maximum number of I/O expansion module:
 7 (local)
 14 (remote)

Supply voltage limits: 20.4…28.8 V
Inrush current: 50 A
Power consumption in W: 32.6…40.4 W (with max number of I/O expansion module)

Memory capacity:
 8 MB for program
 64 MB for system memory RAM

Data backed up: 128 MB built-in flash memory for backup of user programs
Data storage equipment: <= 16 GB SD card (optional)
Battery type: BR2032 lithium non-rechargeable, battery life: 4 year(s)
Backup time: 2 years at 25 °C

Execution time for 1 KInstruction:
 0.3 ms for event and periodic task
 0.7 ms for other instruction

Execution time per instruction: 0.022 µs

Application structure:
 3 cyclic master tasks + 1 freewheeling task
 8 event tasks
 4 cyclic master tasks
 8 external event tasks
 
Realtime clock: With
Clock drift: <= 60 s/month at 25 °C

Integrated connection type:
 USB port with mini B USB 2.0 connector
 Non isolated serial link serial with RJ45 connector and RS232/RS485 interface
 Dual-port Ethernet with RJ45 connector
 CANopen J1939 with SUB-D 9 connector

Supply: (serial)serial link supply: 5 V, <200 mA

Transmission rate:
 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
 480 Mbit/s for bus length of 3 m for USB

Communication port protocol:
 USB port: USB - SoMachine-Network
 Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network

Port Ethernet: Ethernet marking 10BASE-T/100BASE-TX - 2 copper cable
Web services: Web server

Communication service:
 DHCP client
 Downloading
 Ethernet/IP slave device
 IEC VAR ACCESS
 Modbus TCP client
 Modbus TCP server
 Modbus TCP slave device
 Monitoring
 NGVL
 Programming
 Updating firmware
 SMS notifications
 FTP client/server
 SNMP client/server
 SQL client
 Send and receive email from the controller based on TCP/UDP library
 Web server (WebVisu & XWeb system)
 OPC UA server
 DNS client

Maximum number of connections:
 8 Modbus server
 8 Modbus client
 16 Ethernet/IP target
 4 FTP server
 10 web server
 8 SoMachine protocol

PLC Schneider

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1



Silahkan email permintaan Anda ke:
 

 


marketing@ato.co.id


 
 

Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot